Emitter, receiver or SIM-P module swap: Useful information
Atanytime,onecanreplacetheemitter,thereceiverortheSIMPmodule.Someofthese
replacementsaretransparentintheoperationofthephotocell,somearenot.Theparametersare
storedintheSIMPmodule.Afterapowerup,theparametersarereadfromtheflash
memoryof
theSIMPfornormaloperation.ThereceivercontainsamemorybackupoftheSIMP’sparameters.
Theparameterscanberetrievedifnecessary.Theemitterhasnomemorytostoreparameters.In
thefollowingparagraph,eachcomponentisdescribed.
Emitter
Theemittercanbereplacedwithoutanyinfluenceonthephotocelloperation.WhentheSIMP
detectsthereceiver,alltheactualparametersneededtooperatecorrectlyaresenttotheemitter.
Assoonastheemitterhasreceivedtheparameters,thephotocellstartstofunction.
Receiver
Anemittercanbereplacedwithoutanyinfluenceonthephotocelloperation.Thereceiverhowever
hasthebackupmemoryoftheSIMPmodule.Whenyoumodifyit,theactualbackupisnolonger
available.IfyoureplacethereceiverandtheSIMPmoduleatthesametime,youcannot
operate
thephotocellasitwasworkingbeforethechange.TrytoavoidreplacingthereceiverandtheSIM
duringthesamepowerdownoperation.ToupdatethebackupmemoryoftheSIMPmodule
insidethenewreceiver,youneedtofollowoneofthesesteps:
Modify oneparameterintheSIMPmodule.Everytimeaparameterischanged,the
completememoryissenttothereceivermemoryforbackuppurposesautomatically.Any
changeofaparametermakesafullupdateinthereceivermemory.
Executethe“saveparameter”commandfromtheSIMPcommandmenu.Thiscommand
willtakethedataintheSIMP’sparametermemoryandsenditdirectlytothereceiver’s
memorytoupdatethenewreceiver
SIMPmodule
WhentheSIMPmoduleisreplaced,theparameter’smemoryisgonewiththeoldSIMPmodule. It
meansthatthephotocellwillnotworkasitwasworkingbeforetheSIMPmoduleswap.Youcan,
however,retrievealloftheoldparametersfromthereceiverbydoingthe
following:
Executethe“retrieve”commandfromthenewSIMPmodule.Thiscommandmustbeexecuted
beforeanyparametersarechanged.Ifaparameterischangedfirst,youwillloseallthebackup
parametersavailableinthereceiverhead.