6.4 Technical data Receiver G5 M19
1
12
2
11
3
10
4
9
5
8
6
7
7
6
8
5
9
4
10
3
11
2
12
1
A1 = Output/input 16
A2 = Output/input 15
A3 = GND
A4 = Output/input 14
A5 = Estop
A6 = Power Supply +
A7 = Output 1
A8 = Output 2
A9 = Output 3
A10 = Output 5
A11 = Output 4
A12 = Output/input 6
B1 = Output/input 7
B2 = Output/input 8
B3 = Output/input 9
B4 = Output/input 10
B5 = Output/input 11
B6 = Output/input 12
B7 = RS232 TX
B8 = RS232 RX
B9 = Output/input 13
B10 = Output/input 17
B11 = Output/input 18
B12 = Output/input 19
Attribute Information
Power Supply 9-36 VDC
IP-Class IP67
Connector Interface 2 x 12 pin Deutsch connectors
Programming interface RS232
Overload Protection Yes, maximum 36 VDC
Current consumption <30 mA (idle), 60 mA + External loads in operation
Digital Inputs 14 (can also be used as digital outputs) Do not exceed supply voltage.
Digital Outputs 19 MOSFET driven outputs, Short circuit proof, overload protected.
E-Stop Output Active when system is operational, short circuit proof, overload pro-
tected.
Max output load 3A/output, 5A/bank, 10A/system
Bank 1 2 3 4 5 6 7 8 9
10
Output 1,Estop 2,3 4,5 6,16 7,9 8,10 11,12 13,17 18,19
14,15
Housing screw torque 0.8 Nm
Ambient Temperature -25°C to +70°C ~ -15°F to +160°F
Weight 0,5 Kg ~ 1.10 lbs
18/33