6.6 Technical data G5 Receiver CAN
Attribute Information
Power Supply 9-36 VDC
IP-Class IP67
Connector Interface
3x M12 connectors with 3 meter cable each, see specication below
Programming interface RS232
Overload Protection Yes, maximum 36 VDC
Current consumption
Idle: 65 mA (at 24V)
Operational: 100 mA + External loads in operation (at 24V)
Digital Outputs
Short circuit proof, overload protected, max. 2,7 Ampere load
DV2 is active when radio link is active.
Safety loops Feed Loop-In with power supply. Once radio link is established, Loop-Out goes
high. Short circuit proof. Max 2,7 Ampere load.
CAN bus CAN Open
Ambient Temperature -25°C to +70°C ~ -15°F to +160°F
Weight 1,2 Kg ~ 2.6 lbs
Connection
Pin no. Colour /Function
1 Brown / Not used
2 White / Power supply + 12/24VDC
3 Blue / GND / CAN_GND
4 Black / CAN_HIGH
5 Grey / CAN_LOW
Connection
Pin no. Colour /Function
1 Brown / Not used
2 White / GND
3 Blue / RS 232 TX
4 Black / RS 232 RX
5 Grey / Not used
Connection
Pin no. Colour /Function
1 Brown / DV2+
2 White / LOOP1_OUT
3 Blue / LOOP1_IN
4 Black / LOOP2_OUT
5 Grey / LOOP2_IN
Cable C
Cable B
Cable A
2
2
1
1
3
3
5
5
4
4
5-pole
M12 connector
5-pole
M12 connector
male
male
1 2
5
4 3
5-pole
M12 connector
female
20/33