Switch off the engine and keep it away from heat,
sparks and ames.
Refuelling only outdoors.
Immediately clean up spilled petrol.
8. Operation
8.1 Starting the engine
Vent the tank lid to „ON“ position (Fig. 4 Pos. A)
Fuel tap switch on position “ON” (Fig. 5 Pos. 3)
In "warm" condition
Starting the engine with the recoil starter ; there-
for tighten handle sharply. Attach the recoil starter
gently and slowly by hand in the original position.
If the engine hasn't started yet, tighten the handle
further. (Fig. 5 Pos. 4)
In "cold" condition
Press the fuel pump a few time if it´s necessary un-
til you see what fuel is pumped through the line.
Move the choke lever to the “RUN” position (Fig. 6)
Starting the motor with the recoil starter; therefor
tighten handle sharply. Attach the recoil starter
gently and slowly by hand in the original position.
If the engine hasn’t started yet, tighten the handle
further. (Fig. 5)
Note:
When the engine is started the rst time, several at-
tempts are necessary for starting up to transport the
fuel from the tank to the engine.
Move the choke lever after starting the motor (after
approx. 15-30 s) to the “RUN” position. (Fig. 6)
8.2 Switching off the engine
Let the generator run briey without load before
you turn it off, so that the aggregate can “recooling”
Move the Fuel tap switch to position “OFF” (Fig. 5)
8.3 Oil warning light (13)
Display is active at low oil level and deactivated when
sufcient oil level.
8.4 Overload indicator (14)
Overload protection is active at too high a power
take-off - Turns off 230 V sockets (10).
Turn off the unit (see section 8.2).
Connected devices from separate generator. The unit
(see section 8.1).
8.5 Operating display (15)
Power indicator active - when the engine is running.
8.6 Energy saving switch (9)
Reduce fuel consumption / idle - Energy saving
switch „ON“ position.
7. Before starting up
m ATTENTION!
Always check before starting the engine:
Check the fuel level and top it up if necessary
- the tank should be at least half lled
Make sure that the generator has sufcient ventila-
tion
Make sure that the ignition cable is secured to the
spark plug
Disconnect possibly connected electronical device
from the generator
Condition of the air lter
Condition of the fuel lines
The external bolt connections for tightness
Attention! Fill the oil before rst use.
Before each use, check the oil level with the engine
switched off and on a level surface. Use the highest
quality four-stroke oil or an HD oil with the same level
of quality.
SAE 10W-30 is recommended for general use at all
temperatures.
Checking the oil level, g. 9
Remove the engine cover (Fig. 6-7)
Remove the oil ller cap (D) and wipe the dipstick
clean.
Check the oil level by inserting the dipstick into the
lling nozzle without screwing the cap on.
If the oil level is too low, rell with the recommended
oil up to the lower rim of the oil lling nozzle.
Filling with fuel
To refuel - cap (2) open counter clockwise.
Fill fuel tank in
Closing tank - tank cap (2) clockwise.
Recommended fuel
Unleaded regular gasoline with a research octane
number of 91 or higher is required for this engine.
Use only fresh and clean fuel.
m Water or impurities in the petrol damage the fuel
system.
Tank volume: 3,2 litre
m Refuel in a well-ventilated area with the
stopped engine. If the engine has been running,
allow it to cool rst. Never refuel the engine in-
side a building where gasoline fumes may reach
ames or sparks.
Petrol is highly ammable and explosiv. You can
get burns or other serious injuries when handling
fuel.

Table of Contents

Other manuals for Scheppach SG2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Scheppach SG2000 and is the answer not in the manual?

Scheppach SG2000 Specifications

General IconGeneral
Fuel typeGasoline
Noise level71 dB
Rated power2000 W
Cooling typeAir
Maximum power2100 W
Rated voltage230 V
Uncertainty K3 dB
Ignition system-
Rated frequency50 Hz
Fuel consumption1.07 l/h
Number of outlets3
Sound power level95 dB
Fuel tank capacity3.2 L
AC outlets quantity2 AC outlet(s)
Engine displacement105.6 cm³
Number of cylinders1
Sound pressure level75 dB
Engine number of strokes4
Operating temperature (T-T)0 - 40 °C
International Protection (IP) codeIP23
Castor wheelsNo
Product colorBlack, Blue
Oil tank capacity0.35 L
Carrying handle(s)Yes
Weight and Dimensions IconWeight and Dimensions
Weight20400 g

Related product manuals