Schindler 3100/3300/6300 J 43402603 / 01 150/269
Copyright © 2017 INVENTIO AG
31 71 Half brake up insufficient shaft height
31 72 Safety gear car test unexpected stop
31 73 Safety gear with empty car test unexpected stop
31 74 AAT STM MONITORING CAR NOT AT CONTROL CABINET FLOOR
31 75 AAT STM MONITORING CANCELED
31 76 AAT STM MONITORING ABORTED
Code CANIO Message
3201
to
3216
CANIO PCB errors. Not used with Schindler 3100/3300/6300
If one of these errors occurs: Please contact a specialist or hotline Locarno.
Code TSD Message
3301
N-KNET IN NON TSD
The elevator has detected a change of the signal KNET (state of triangle key at
landing door) which is only used together with TSD (temporary safety device)
but the TSD is not detected as present.
C1:The wiring at the signal KNET is faulty
A1:Check general wiring
3302
JREC IN TSD
The elevator has detected a change of the signal JREC (state of inspection
switch on top-of-car inspection panel) which is only used together with
standard top-of-car inspection but the standard top-of-car inspection is not
detected as present. TSD (temporary safety device) is detected as present
instead.
C1:The wiring at the signal JREC is faulty
A1:Check general wiring
C2:The elevator main controller board was exchanged by a board from
another elevator
A2:Perform the learning travel. At no success replace elevator main
controller board (for example, SCIC, SCPU) by a new one from the
factory.
3303
ELEVATOR KSR-A IN NON TSD
The elevator has detected a change of the signal KSR_A (state of TSD lever)
which is only used together with TSD (temporary safety device) but the TSD is
not detected as present.
C1:The wiring at the signal KSR_A is faulty
A1:Check general wiring
C2:The elevator main controller board was exchanged by a board from
another elevator
A2:Perform the learning travel. At no success replace elevator main
controller board (for example, SCIC, SCPU) by a new one from the
factory.
Code AAT Message