Schindler 3100/3300/6300 J 43402603 / 01 157/269
Copyright © 2017 INVENTIO AG
3571
SAFETY CIRCUIT OPENED AT ISPT
Safety circuit opened unexpected (for example, during trip) at tap 'ISPT'
C1:The car speed governor rope tension is too low (for example, KSSBV)
A1:Check why the car speed governor rope tension is too low.
C2:The pit ladder is not retracted
A2:Retract pit ladder
C3:Safety circuit wiring faulty or safety circuit contact(s) defective or bad
adjusted
A3:Check general wiring safety circuit and safety circuit contacts at
corresponding safety circuit section
3573
SAFETY CIRCUIT OPENED AT IRTS
Safety circuit opened unexpected (for example, during trip) at tap 'IRTS'
C1:At least one landing door has opened (for example, KTS)
A1:Check why the corresponding door has opened
C2:Safety circuit wiring faulty or safety circuit contact(s) defective or bad
adjusted
A2:Check general wiring safety circuit and safety circuit contacts at
corresponding safety circuit section
3575
SAFETY CIRCUIT OPENED AT IUSK
Safety circuit opened unexpected (for example, during trip) at tap 'IUSK'
C1:The power supply of the safety circuit is faulty
A1:Check operation of power supply (for example, fuses, input power
etc.)
C2:Earth fault
A2:Check safety circuit for short circuit to earth
3582
SAFETY CIRCUIT TEST CAR FAILURE
The circuitry for detecting the door illegal bypass is defect on the car
3583
SAFETY CIRCUIT TEST SHAFT FAILURE
The circuitry for detecting the door illegal bypass is defect in the control cabinet
3584
SAFETY CIRCUIT MANUAL BYPASS BEGIN
The maintenance person removed connector on bypass socket
3586
SAFETY CIRCUIT MANUAL BYPASS END
The maintenance person placed "NORMAL" connector on bypass socket
3587
SAFETY CIRCUIT TEST TAP CAR FAILURE
The controller detects that one of the following taps: IKTC, IRTTC, I2KTC fails
to work
3588
SAFETY CIRCUIT TEST FAILURE
The controller detects a generic failure on safety chain
3589
SAFETY CIRCUIT MANUAL BYPASS INVALID
The maintenance person placed "LAND" connector on bypass socket with
automatic door system
3590
SAFETY CIRCUIT MANUAL BYPASS HW FAILURE
The elevator detects an HW failure on the bypass socket
Code Safety Chain Message (SIAP)