Example of an SMS configuration content:
Return of Stored
Configuration
Notification The ETMA WL will notify only about the following events:
Battery defect
Battery low in power failure
Switch off in power failure
Passenger entrapped.
The notification of the events happens by sending an SMS to the pre-configured
number(s) with following content:
A reboot of the device will reset the flags, which means that the message will be sent
again if the event is still there.
The flags shall be reset in any case after 24 hours.
OEM-Config
SERNO
1234567890
#
OEM-return
Installation ID: 123456789012
ANUM1: +4141123456
ANUM2: +4141123457
ANUM3:
ANUM4:
LNUM: +41414567895
SNUM1: +4179123458
SNUM2: +4179123459
SNUM3: +4179123460
SNUM4:
#
OEM-notify String Declaration as a Notification SMS
Installation ID:
123456789012
// example of a number for the SV_ID (maximum
12 characters long)
Shaft ID: 1 // example of shaft ID
Message: Battery defect // example of a notification message
#