Schindler 3100/3300/6300 J 43402603 / 01 42/269
Copyright © 2017 INVENTIO AG
Recovering from
Third Party
Configuration
Once the ETMA WL is configured with third party, it is not possible anymore to recover to
the factory state. In this case, contact the Schindler second level support.
Factory reset command with DTMF or with the PTT button on the device will only reset
the SMS phone numbers and as well the installation ID.
Communication with
ETMA
The communication of ETMA WL with the call center is same as done for ETMA PSTN.
Refer to paragraph "Configuration Call" in section "ETMA (Embedded Telemonitoring
Alarm)".
Automatic Periodical
Call Procedure
2)
If the alarm device answers with #99# then the TA device did not get the DTMF
commands right. Try again to send the command.
Rescue Service Handling from → to Remote Alarm Device
Establish
Connection
← ring - The TA device dials the
rescue alarm number
- the rescue service
answers the
incoming call
Verify
Installation
ID
- ask the Installation
ID with
#10# →
←
#12xxxxxxxxxxxx#
- sends Installation ID
(x=0 to 999999999999)
Verify Unit
ID
- ask the Unit ID
with
#13# →
←
#14abcd# - sends Unit ID
(a=1 to 8)
(b=1: test call)
Set Line
Test Timer
- Set line test timer
(x = 0 to 99999
minutes)
#74xxxxx#→ - sets line test timer
←
#00#
2)
- sends ok
Close
Connection
- send the hang up
signal
#24# →
- the rescue service
hangs up
←
#00#
2)
- sends ok
TA device hangs up the
phone line