Schindler 3100/3300/6300 J 43402603 / 01 46/269
Copyright © 2017 INVENTIO AG
Operation Priorities – In case the inspection and emergency recall panels are made active, the priorities
are defined as follows from HIGH to LOW:
– Inspection in pit OR inspection top of car
– Emergency recall in machine room / control cabinet
– In case inspection top of car and inspection in pit are made active at the same time,
NO movement of the car is allowed.
– The concurrent pressing of up or down buttons on inspection panel top-of-car AND
inspection panel in pit are NOT supported.
Priority Decision
Priority Decision Table
Emergency Recall
Operation from
outside Hoistway
Emergency Recall Panel ESE [604620_034; 07.12.2015]
JREC Active Inactive Inactive Active
JRESG Inactive Active Inactive Active
JRH - - Active -
Inspection Top of Car X
Inspection in Pit X
Emergency Recall X
No Movement X
No Step
1
Activation:
– Press JHM
– Switch JRH to "Inspection"
– Release JHM only if JRH has been switched to "Inspection"
2 Operation:
– Press and hold DRH_U to move the car upwards
– Press and hold DRH_D to move the car downwards
– Release DRH_U or DRH_D to stop the car movement
– Press JHM to stop the car movement
3 Deactivation:
– Switch JRH to "Normal"
– Check that JHM is not pressed
JHM
DRH_U
DRH_D
JRH
STOP
UP
DOWN
NORM.
INSP.