Lock assembly drawing index
Schlage • L-Series service manual • 11
L9000 FUNCTIONS
ANSI/BHMA A156.13, 1994, Series 1000, Grade 1
Keyed locks
Trim
assembly
page no.
Lock
assembly
page no.
Lock case
part no.
SCHLAGE ANSI Description
LV9077 Classroom security holdback lock† with Vandlgard
®
z
Latchbolt is retracted by knob/lever from either side unless locked by key from
either side. When locked, latchbolt is retracted by key outside or knob/lever
inside. Auxiliary latch deadlocks latchbolt when door is closed. Turn/depress
inside knob/lever and turn key 360° for holdback feature. Vandlgard function
allows exterior lever to rotate freely down while remaining securely locked.
29 67 L283-172
L9080 F07 Storeroom lock z
Latchbolt is retracted by key outside or by knob/lever inside. Outside knob/lever
is always inoperative. Auxiliary latch deadlocks latchbolt when door is closed.
Inside knob/lever is always free for immediate exit.
30 68 L283-134
LV9080 Storeroom Lock with Vandlgard
®
z
Latchbolt is retracted by key outside or by knob/lever inside. Outside knob/lever
is always inoperative. Auxiliary latch deadlocks latchbolt when door is closed.
Inside knob/lever is always free for immediate exit. Vandlgard function allows
exterior lever to rotate freely down while remaining securely locked.
30 69 L283-173
L9080EL Electrically locked (fail safe) z
Outside knob/lever is continuously locked. Latchbolt is retracted by key outside
or by knob/lever inside. Switch or power failure allows outside knob/lever to
retract latchbolt. Auxiliary latch deadlocks latchbolt when door is closed. Inside
knob/lever is always free for immediate exit.
30 72 L283-142
LV9080EL Electrically locked (fail safe) with Vandlgard
®
z
Outside knob/lever is continuously locked. Latchbolt is retracted by key outside
or by knob/lever inside. Switch or power failure allows outside knob/lever to
retract latchbolt. Auxiliary latch deadlocks latchbolt when door is closed. Inside
knob/lever is always free for immediate exit. Vandlgard function allows exterior
lever to rotate freely down while remaining securely locked.
30 73 L283-174
L9080EU Electrically unlocked (fail secure) z
Outside knob/lever is continuously unlocked. Latchbolt is retracted by key
outside or by knob/lever inside. Inside knob/lever is always free for immediate
exit. Auxiliary latch deadlocks latchbolt when door is closed.
30 74 L283-143
LV9080EU Electrically unlocked (fail secure) with Vandlgard
�
z
Outside knob/lever is continuously unlocked. Latchbolt is retracted by key
outside or by knob/lever inside. Inside knob/lever is always free for immediate
exit. Auxiliary latch deadlocks latchbolt when door is closed. Vandlgard function
allows exterior lever to rotate freely down, while remaining securely locked.
30 74 L283-175
L9080EL-RX Request to exit electrically locked (fail safe)
Same as L9080EL function. In addition, a microswitch
positioned inside the lock case is activated when either inside or outside knob/
lever is rotated. The switch signals the use of that opening to security systems,
allowing a non-disruptive means of immediate exit. Specify L283-263.
(Previously XL11-807)
30 72 L283-142
per
L283-263
† Locks with holdback feature are not UL listed. Installation should be in accordance with existing codes only.
* Caution: Double cylinder locks on residences–or on any door in any structure which are used for egress–are a life safety hazard in times of
emergency, and their use is not recommended. Installation should be in accordance with existing codes only.
Not sold separately as a part.
z Available with Request to Exit feature.