Request to exit (RX) feature
Request to exit (RX) feature
A microswitch inside the lock case is activated when the knob/lever is rotated. The switch signals the use of that opening to
security systems allowing a non-disruptive means of immediate egress. Specify the L-Series lock case with L283-263, or
the LV-Series lock case with L283-239.
L-Series RX Switch
black (common)
yellow
(NO)
blue
(NC)
LV-Series RX Switch
black
(common)
yellow
(NO)
blue
(NC)
Note: Locks shipped prior to mid-2010 are configured with two-wire switches: L283-059 for normally closed or L283-125
for normally open L-Series, and L283-197 for normally closed or L283-196 for normally open LV-Series.
Request to Exit feature is available on the following L and LV Series locks: L9080EL/EU, L9010, L9050, L9060, L9070,
L9071, L9076, L9077, L9080, L9056, L9496, L9453, L9456, L9457, L9082 EL/EU.
Latch monitoring
A microswitch inside the lock case is activated when the latch is retracted.
Available only on L9080EL-RX and L9080EU-RX functions. Specify XL12-245 for
L9080PEL, or XL12-246 for L9080PEU.
White (common)
Purple
(NO)
Grey (NC)