Assembly
12.00 | SWS | Assembly and Operating Manual | en | 389456
79
Mount sensor assembly on SWK
Mount sensor assembly on SWK
Ø Protect the threads of the detection shaft(6) from lubricant
with a strip of adhesive tape.
Ø Lubricate the detection shaft(5),
Lubricants/greasing areas [
}
89].
Ø Carefully push the detection shaft(5) into the sensor
assembly(1) up to the stop.
Ø Remove adhesive tape from the thread of the detection
shaft(6).
Ø Apply primer for the screw lock on the thread(6) of the
detection shaft and briefly allow it to dry.
Ø Apply screw lock to thread(6).
Ø Align the sensor assembly(1) with the dowel pin(2) on the
SWK(3).
Ø Secure sensor assembly(1) to SWK(3) with screws(4).
Max. tightening torque: 0.68Nm