OmniHub CMP203– User Manual
Page 40 of 109
Channel Plan
Frequency of RF Channels
Off-Air CH2 57MHz, CH3 63MHz, CH4 69MHz~CH67 791MHz, CH68797MHz,
CH69 803MHz
STD CH2 57MHz, CH363MHz, CH4 69MHz~ CH133 849MHz, CH134855MHz,
CH135 861MHz
IRC CH2 57MHz, CH3 63MHz, CH4 69MHz ~ CH133 849MHz, CH134,
855MHz, CH135 861MHz
HRC CH2 55.75MHz, CH3 61.75MHz, CH4 67.75MHz~ CH133847.75MHz,
CH134 853.75MHz, CH135 859.75MHz
3.3.5.3 Modules Service Configuration
To route a whole stream or service/s from the 8VSB towards the output channel
(stream), use the Service Configuration tab. Two types of routing are possible:
1. Bypass mode routes whole input transport stream towards IP or RF output.
Bypass mode activation cause output channel will be occupied only by this
stream. Any attempt of routing other stream/service towards this channel will
show error. This can only be done when you click the icon on the TS. Bypass
cannot be on the single service only.
2. Multiplex mode is the counter part of bypass mode. This mode allows the
administrator to perform the following operations:
a. Routing single service towards output channel will results in SPTS creation
b. Routing services towards single output channel will results in MPTS creation
c. Routing service/s AND stream/s towards single output channel will results in
MPTS creation
To use Bypass OR Multiplexing mode on stream level click the (cog) icon. There
will have always a BaseBoard selection for the IP output and other Output option
depending on the module inserted. Select the correct Output and Channel you want to