EasyManua.ls Logo

Sencore OmniHub CMP203 - Page 84

Sencore OmniHub CMP203
109 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OmniHub CMP203– User Manual
Page 84 of 109
Command Input Settings specify the incoming PID, IP, and Port of the SCTE-18
triggers over Ethernet cable. The IP EAS IN RJ45 Ethernet port on the module is
where this information must be received.
Encoder Settings section is for the RCA / Analog-AV inputs. When the takeover
content is provided in this fashion it must be encoded to MPEG “.TS” Transport
Stream data. The Video, Audio, and Bitrate settings are used to configure the
format.
IP Output Settings configure the command sent from the EAS module to the encoders.
The settings applied here must match in the EAS tab of each Encoder Module.
Table of all parameters in the EAS module:
Name
Range
Name
Range
Command Input Setting