7
Startup
Startup procedure
Manual – EtherCAT
®
Interfaces, Field Distributors
67
INFORMATION
Switch off the DC 24 V voltage supply before removing/installing the fieldbus inter-
face.
The incoming and outgoing PROFINET IO bus cables are connected to the
module electronics. If the module electronics are removed, the PROFINET IO line
is interrupted.
In addition, observe the notes in chapter "Supplementary Field Distributor Startup
Information" of the manual.
7.2 Startup procedure
INFORMATION
This chapter describes the startup procedure for MOVIMOT
®
MM..D in Easy mode.
For information on the startup of MOVIMOT
®
MM..D in Expert mode, refer to the
"MOVIMOT
®
MM..D" operating instructions.
WARNING
Electric shock from capacitors that have not been fully discharged.
Severe or fatal injuries.
Disconnect the inverter from the power. Observe the minimum switch-off time
after disconnection from the supply system:
1 minute
1. Make sure the MOVIMOT
®
inverter and the EtherCAT
®
interface (MFZ21, MFZ23,
MFZ26, MFZ27 or MFZ28) are installed correctly.
2. Set the S1/1 DIP switch on the MOVIMOT
®
inverter (see relevant MOVIMOT
®
op-
erating instructions) to "ON" (= address 1).
1
ON
6
7
8
543
2
1
ON
2
1158400267
3. Remove the screw plug above the f1 setpoint potentiometer on the MOVIMOT
®
in-
verter.
4. Set the maximum speed using setpoint potentiometer f1.
123456789100
100
f[Hz
[1]
]
2
75
25
50
6
5
f
1
1158517259