Shini Group
Technology & Marketing Dept
Issued by department: Date: Language: Document Name: Revision: Page:
Shini/CSC-TM
2013-11 zh-cn Shini product repair manual.doc
1.0 2 (62)
Catalog:
template:Standard_CN.dot; filename: Shini product repair manual; Printdate: 8/1/2014 1:58:00 PM; savedate: 8/1/2014 1:58:00 PM
Content
Content........................................................................................................................2
1. Introduction..........................................................................................................6
2. Heating Pipe.........................................................................................................7
2.1 Applicable Models..........................................................................................7
2.2 Working Principle...........................................................................................7
2.3 Inspection.......................................................................................................7
2.4 Replacing.......................................................................................................7
3. Dewpoint Detection Device.................................................................................9
3.1 Applicable Models..........................................................................................9
3.2 Products Information......................................................................................9
3.3 Working Principle...........................................................................................9
3.4 Installation and Commissioning......................................................................9
3.5 Alarm Exclusion...........................................................................................10
3.6 Dewpoint Monitor Parameter Settings..........................................................10
3.6.1 Remove Dewpoint Monitor Lid...........................................................10
3.6.2 How to Set Parameters......................................................................11
4. Temperature Controller TU-01..........................................................................12
4.1 Applicable Models........................................................................................12
4.2 Products Information....................................................................................12
4.3 Working Principle.........................................................................................12
4.4 Alarm Exclusion...........................................................................................12
4.4.1 E-01/Temperature Line Breaking Alarm E-01....................................12
4.4.2 Anti-phase Alarm E-02.......................................................................13
4.4.3 Input Overload Alarm E-03................................................................13
4.4.4 Actual temperature exceeds EGO setpoint—Over heat alarm E-04..14
4.4.5 Actual temperature exceeds the maximum temperature—Over heat
alarm E-05....................................................................................................14
4.4.6 Actual temperature is higher than the sum of set temperature and
alarm temperature—Over-temperature alarm E-07......................................15
4.4.7 Memory Error E-08............................................................................16
4.4.8 Honeycomb-rotor Fault Alarm............................................................16
4.4.9 Actual temperature exceeds EGO setpoint—Over-temperature alarm
E-10 16
4.4.10 Thermocouple Polarity False Alarm E-11..........................................16
4.4.11 PID Self-tuning Wrong E-12...............................................................16