14.2 Cooler housing
235 (9.25)
135 (5.31)
305 (12.01)
345 (13.58)
154 (6.06)
51
.5°
51.5°
R74
M10
10.5
(0.41)
26
(1.02)
Figure 28: Cooler housing; unit: mm (inch), decimal separator: period
Table 70: Cooler housing
Description Cooler housing including sensor-specific adapter plate and BEF-
AH-DME alignment bracket (part number: 2027721)
Type TPCC-Dx100
Part number 6048328
Material Plastic (polyamide 6)
Weight 7.5kg
Ambient temperature,
operation
–40 … +75°C (+80°C for max. 1h)
Ambient temperature stor‐
age
–40 … +50°C
Supply voltage 24 ... 30VDC
Current consumption 11A at 24VDC; start-up current max. 15A at 24VDC
Enclosure rating IP55 (horizontal mounting)
IP54 (vertical mounting)