Input Description
C1
(opt
ional)
Data type: Boolean
The optional C1 input can be used as additional protection against
manipulation. If it is used, the C1 input must have switched to 0 after a
previous muting cycle, and to 1 at the latest when both muting sensor
signal inputs switch to 1 at the same time. A failure to meet this
condition results in a muting error, which is indicated at the Muting error
output.
The C1 input must then switch back to 0 before the subsequent muting
cycle is permitted. The C1 input is not relevant for the duration of the
muting status.
Table 110: Outputs
Output Description
Enable Data type: Boolean
Muting lamp Data type: Boolean
The Muting lamp output can be used to indicate when a muting cycle is
active.
The Muting lamp output = 0 if the Muting status output = 0
The Muting lamp output = 1 if the Muting status output = 1 or the
Override status output = 1
The Muting lamp output pulsates at 2 Hz if the Override required output
= 1
Muting status Data type: Boolean
The output indicates the status of the muting function.
The Muting status output = 0 if the muting cycle is inactive (no error)
or a muting error has been detected
The Muting status output = 1 if the muting cycle is active (no error) or
override is active (no error)
Override required Data type: Boolean
Muting error Data type: Boolean
"Output Muting error", page 103
Override status Data type: Boolean
Status Data type: Boolean
0 = Er
ror
1 = No error
The value at the output is the inverted value of the Muting error output.
Table 111: Parameter
Parameter Description
Direction detection
Dis
abled
Forward (A1 / A2 first)
Backward (B1 / B2 first)
"Parameter Direction detection", page 104
Condition of the other sen‐
sor pair f
or muting start
Bo
th sensors are free
At least one sensor is free
"Parameter Condition of the other sensor pair for muting start",
page 105
Condition for end of muting
W
ith muting sensor pair
With electro-sensitive protective equipment (ESPE)
"Parameter Condition for end of muting", page 105