Systematic error
1)
± 38mm up to 80m
± 63mm from 80m
Temperature drift: typ. ± 0.6mm/K
Statistical error
1)
≤ 30mm (at 20 ... 90% remission)
Measurement resolution 1/256m up to 250m in the USP interface; 4mm to 250m
(CoLa-A/B)
Integrated application (LD-
LRS3600 only)
Field evaluation
Number of field sets (LD-
LRS3600 only)
6
Simultaneous evaluation
cases (LD-LRS3600 only)
10
1)
Typical value; actual value depends on ambient conditions
10.4 Interfaces
Ethernet TCP/ IP
Data transmission rate: 100Mbit/s
Protocols:
CoLa-A/B (port 2112)
CoLa-A (port 2111)
lD-LRS3611 only: USP (port 49152)
Serial RS-422
Data transmission rate: 19,200baud ... 115,200baud
Data format: Variable, default: 8 data bits, 1 stop bit, no parity
Protocol: CoLa-A
Optical displays None
Digital outputs 4
Configuration software SOPAS ET, web server (display only)
TECHNICAL DATA 10