2 Safety information
2.1 Intended use
The LD-LRS 2D LiDAR sensor is intended exclusively for use in industrial environments.
Radio interference may result when used in residential areas.
The LD-LRS automates ship loading operations when using ship-to-shore cranes. The
laser optics system performs non-contact scanning of the container stack and precisely
detects all obstacles impeding the loading. The precise measurement data from the
LD-LRS is used to determine the profile data of the container stacks.
The profile measurement of the filling condition of bulk material stockpiles can be
converted into a 3D model to determine the exact surface structure of the stockpile to
control the loading system.
In conjunction with the field application, the LD-LRS can also be used for building safety
and security and for monitoring a variety of access zones outdoors.
Possible fields of application
Container automation: position determination and detection
Piece goods: measurement of the shape, position and volume of objects
Crane control: profile measurement, collision protection, position detection and
guidance
Surveying: floor plan surveying, longitudinal and transverse profiles in buildings
Buildings: object protection, access monitoring, protection of facades and areas
(LD-LRS3600 only)
SICK AG assumes no liability for losses or damage arising from the use of the product,
either directly or indirectly. This applies in particular to use of the product that does not
conform to its intended purpose and is not described in this documentation.
2.2
Improper use
Any use outside of the stated areas, in particular use outside of the technical specifica‐
tions and the requirements for intended use, will be deemed to be incorrect use.
The device does not constitute a safety component in accordance with the respec‐
tive applicable safety standards for machines.
The device must not be used in explosion-hazardous areas, in corrosive environ‐
ments or under extreme environmental conditions.
Any use of accessories not specifically approved by SICK AG is at your own risk.
WARNING
Danger due to improper use!
Any improper use can result in dangerous situations.
Therefore, observe the following information:
Product should be used only in accordance with its intended use.
All information in the documentation must be strictly observed.
Shut down the product immediately in case of damage.
2.3 Cybersecurity
Overview
To protect against cybersecurity threats, it is necessary to continuously monitor and
maintain a comprehensive cybersecurity concept. A suitable concept consists of organi‐
zational, technical, procedural, electronic, and physical levels of defense and considers
SAFETY INFORMATION 2
8016506/1G07/2020-11-08 | SICK O P E R A T I N G I N S T R U C T I O N S | LD-LRS
7
Subject to change without notice

Table of Contents

Related product manuals