OPERATING INSTRUCTIONS | LFP INOX 8019921/15H0 / 2019-09-30| SICK AG
Irrtümer und Änderungen vorbehalten
11
3PRODUCT DESCRIPTION
3 Product description
3.1 Product ID
3.1.1 Information on the housing
Information for identication of the sensor and its electrical connection are printed on
the housing.
3.1.2 Type code
LFP x - x x x M x x
1 2 3 4 5 6 7 8
Position Description
1 Product group
LFP (level sensors)
2 Probe length in mm
0200:
20 mm (in increments of 10 mm)
4000:
4000 mm
3 Process connection / probe version
G: G ¾ A (connection for hygienic adapter) / probe rod from 1.4404
N: ¾" NPT / probe rod from 1.4404
4 Housing, display / device connection
1: Stainless-steel housing with display, cover with sight glass /
5-pin M12 x 1 male connector
2: Stainless-steel housing with display, solid cover /
5-pin M12 x 1 male connector
3: Stainless-steel housing 3-A compliant with display, solid cover /
5-pin M12 x 1 male connector
6: Stainless steel housing with display, cover with sight glass;
8-pin M12 x 1 male connector
7: Stainless steel housing with display, solid cover;
8-pin M12 x 1 male connector
A: Stainless steel housing with display, cover with sight glass;
5-pin cable connection
B: Stainless steel housing with display, solid cover;
5-pin cable connection
C: Stainless steel housing with display, cover with sight glass /
8-pin cable connection
D: Stainless steel housing with display, solid cover;
8-pin cable connection
5 Application type / design
B: remote amplier; length of cable 1 m
C: remote amplier; length of cable 2 m
D: remote amplier; length of cable 3.3 m
N: Standard
6 Signal output
M: 4 mA … 20 mA / 0 V … +10 V switchable
7 Switching output
B: 1 x PNP + 1 x PNP/ NPN
8 Device type
L: LABS-compatible
Not all variants of the type code can be combined!