OPERATING INSTRUCTIONS | LFP INOX 8019921/15H0 / 2019-09-30| SICK AG
Irrtümer und Änderungen vorbehalten
61
17ACCESSORIES
17 Accessories
Note:
Hygienic connection adapters may only be screwed on once. The tightening torque for
the connection adapter should be at least 15 Nm and no more than 25 Nm. Repeat-
ed opening can damage the gasket and therefore impair the hygienic properties. The
available adapters for hygienic applications are suitable for the LFP basic device with
threaded G ¾ A connection. Process connection gaskets are to be provided by the
customer.
If a leakage is detected at the leakage indication port of the hygienic adapter, the
process must be stopped immediately and the sensor must be replaced by new, intact
sensor.
An overview of EHEDG-compliant seals can be found in the EHEDG Position Paper:
https://www.ehedg.org/guidelines/free-documents/
b Accessories can be found online at: www.sick.com