9 TECHNICAL DATA
104
8026364 / V1-0/2022-03|SICK
SUPPLEMENTARY OPERATING INSTRUCTIONS | VMS4200/5200
Subject to change without notice
9 Technical data
9.1 Data sheet
Type VMS4200 VMS5200
Type Two-scanner solution
Laser output aperture On the front
Laser diode (wavelength) Visible light (λ = 650 nm)
Laser power Max. 13 mW
Laser class of the device 2
Usable aperture angle Max. 70°
Detectable object shape Almost any.
Object dimensions must be at least 50 mm × 50 mm ×
20 mm
Min. object size (L × W × H)
(operating condition 1)
Certified scale value
At v = 0.1 m/s to 4.0 m/s
50 mm x 50 mm x 20 mm / 2.0" x 2.0" x 1.0"
5 mm (0.2") x 5 mm x 2 mm / 0.2" x 0.2" x 0.1"
Min. object size (L × W × H)
(operating condition 2)
Certified scale value
At v = 0.1 m/s to 4.0 m/s
50 mm x 50 mm x 50 mm / 2.0” x 2.0” x 2.0"
5 mm x 5 mm x 5 mm / 0.2” x 0.2” x 0.2"
Min. object size (L × W × H)
(operating condition 3)
Certified scale value
At v = 0.1 m/s to 4.0 m/s
100 mm x 50 mm x 50 mm / 4.0” x 2.0” x 2.0"
10 mm x 5 mm x 5 mm / 0.4” x 0.2” x 0.2"
Min. object size (L × W × H)
(operating condition 4)
Certified scale value
At v = 0.1 m/s to 4.0 m/s
100 mm x 100 mm x 50 mm / 4.0” x 4.0” x 2.0"
10 mm x 10 mm x 5 mm / 0.4” x 0.4” x 0.2"
Min. object size (L × W × H)
(operating condition 5)
Certified scale value
At v = 0.1 m/s to 4.0 m/s
100 mm x 100 mm x 100 mm / 4.0” x 4.0” x 4.0"
10 mm x 10 mm x 10 mm / 0.4” x 0.4” x 0.4"
Min. object size (L × W × H)
(operating condition 6)
Certified scale value
At v = 0.1 m/s to 4.0 m/s
100 mm x 50 mm x 20 mm / 4.0” x 2.0” x 1.0"
10 mm x 5 mm x 2 mm / 0.4” x 0.2” x 0.1"
Min. object size (L × W × H)
(operating condition 7)
Certified scale value
At v = 0.1 m/s to 4.0 m/s
100 mm x 100 mm x 20 mm / 4.0” x 4.0” x 1.0"
10 mm x 10 mm x 2 mm / 0.4” x 0.4” x 0.1"