7 MAINTENANCE AND REPAIR
8026364 / V1-0/2022-03|SICK
SUPPLEMENTARY OPERATING INSTRUCTIONS | VMS4200/5200
Subject to change without notice
7.2.3 Replacing the incremental encoder components
If the incremental encoder is defective, it must be replaced immediately.
Part no. Meaning
2058477 DFV60 incremental encoder
WARNING
Do not violate LFT mode on the VMS5200.
The VMS5200 multi-dimensional measurement system is operated in LFT mode.
▸
Do not replace the incremental encoder yourself.
▸
Do not break any adhesive seals.
If repairs are required, contact the manufacturer.
▸
Unscrew the M12 plug connection from the male connector on the incremental
encoder.
▸
Loosen and remove the fixing screws.
Fig. 72: Replacing the incremental encoder
▸
Mount the replacement device on the conveyor belt (for more information, see section
4.2 Mounting the incremental encoder).
NOTE! Observe the correct mounting direction.
▸
Screw the M12 plug connection onto the male connector on the incremental encoder.
Replacement
device
Removing a
defective encoder
Mounting the
replacement device