3 SYSTEM DESCRIPTION
8026364 / V1-0/2022-03|SICK
SUPPLEMENTARY OPERATING INSTRUCTIONS | VMS4200/5200
Subject to change without notice
3.7.3 Mounting requirements
▸
Use a stable frame that is secured to prevent twisting and has sufficient load-bearing
capacity.
▸
Attach the frame to the conveying system in such a way that it cannot shake or vibrate.
▸
Align the frame at a right angle to the conveying direction.
NOTE! Use Item aluminum profiles.
Fig. 43: Working range of the LMS4x21
Legend
1 Maximum working sensing range: 3 m
2 Zero point of the distance measurement. In the delivery state, this point
is the origin of the laser (marked with a point on the upper and lower
side of the housing).
3 Minimum distance between the zero point of the measurement and the
measuring object: 900 mm
4 Aperture angle: 70°
Frame
LMS4x21