SYSTEM DESCRIPTION 3
37
8026364 / V1-0/2022-03|SICK
SUPPLEMENTARY OPERATING INSTRUCTIONS | VMS4200/5200
3.6.2 Security seal
In order to protect measurement systems that have been verified as legal for trade
against manipulation, all legally relevant components that influence the measurement
result must be provided with seals in accordance with the seal diagram depicted in the
figure below.
The security seals are attached to the VMS5200 components after mounting and the
conformity check.
NOTE! Never break any seals. A broken seal causes the legal for trade calibration period
to end ahead of schedule. Use of the VMS5200 for billing purposes is then no longer
permitted.
The incident must be reported to the manufacturer and the office of weights and
measures.
Security seals prevent the attachment mechanism of the 2D LiDAR sensors and the plug
connections of the connections from misaligning.
Fig. 24: Security seal on the 2D LiDAR sensors of the VMS5200
Legend
1 Security seal on the mounting plate of the modular bracket on the frame
2 Security seal on the two adjusters of the telescopic tube
3 Security seal on the mounting plates of the 2D LiDAR sensors
4 Security seal on all plug connections for the electrical connections
Seal on the