3 SYSTEM DESCRIPTION
26
8026364 / V1-0/2022-03|SICK
SUPPLEMENTARY OPERATING INSTRUCTIONS | VMS4200/5200
Subject to change without notice
Fig. 15: Data output of the VMS5200
Legend
1
SIM2000-2 Prime controller
1a
Saving of measurement results in alibi memory
1b
Display of measurement results on LFT display
1c
Data output via Ethernet, fieldbus, RS-232 / RS422
During billing-related operation of the VMS5200, before the data is output the
measurement results are saved in the SIM2000-2 Prime controller alibi memory,
which is required for legal-for-trade verification.
The measurement results are also displayed on the LFT display.
Fig. 16: Configuring the time of the data output
Legend
1
Free-running operating mode: issue as soon as possible after leaving the
scanning line.
2
Triggered operating mode: after a defined distance from X position in
relation to the rear edge of an object.
3 Triggered operating mode: after a defined distance from X position in
relation to the leading edge of an object.
The output time is configured using SOPAS.
Issue depends on the triggering mode selected.
VMS5200
data output
Configuring
output times