EasyManua.ls Logo

SICK WTB4S - Communication Interface

SICK WTB4S
260 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Emitted beam
WTB4SP-xxxxx1 WTB4SP-xxxxx2 WTB4ST-xxxxx1
Light sender PinPoint-LED PinPoint-LED LED
Type of light Sichtbares Rotlicht Sichtbares Rotlicht Sichtbares Rotlicht
Light spot size / distance Ø 4,0 mm (150 mm) Ø 1,8 mm (70 mm) 2,5 mm x 16 mm (50
mm)
Communication interface
Table 9: Communication interface
IO-Link
WTB4SP-xxxxx1 WTB4SP-xxxxx2 WTB4ST-xxxxx1
IO-Link 1.1 1.1 1.1
Data transmission rate COM2 COM2 COM2
Electrical data
WTB4SP-xxxxx1 WTB4SP-xxxxx2 WTB4ST-xxxxx1
Supply voltage U
B
DC 10 ... 30 V
1)
DC 10 ... 30 V
1)
DC 10 ... 30 V
1)
Ripple ≤ 5 Vss ≤ 5 Vss ≤ 5 Vss
Current consumption 25 mA 25 mA 25 mA
Protection class III III III
1)
Limit values
Reverse polarity protected U
B
connections
Residual ripple max. 5V
ss
Digital output
WTB4SP-xxxxx1 WTB4SP-xxxxx2 WTB4ST-xxxxx1
Output current I
max.
≤ 100 mA ≤ 100 mA ≤ 100 mA
Circuit protection A, B, D
1)
A, B, D
1)
A, B, D
1)
Response time ≤ 500 µs
2)
≤ 500 µs
2)
≤ 1.000 µs
2)
Switching frequency 1000 Hz
3)
1000 Hz
3)
500 Hz
3)
1)
A = U
B
-connections reverse polarity protected
B = inputs and output reverse-polarity protected
D = outputs overcurrent and short-circuit protected
2)
Signal transit time with resistive load
3)
With light / dark ratio 1:1
8)
Valid for Q\ on Pin2, if configured via software
Mechanical data
WTB4SP-xxxxx1 WTB4SP-xxxxx2 WTB4ST-xxxxx1
Enclosure rating IP66, IP67 IP66, IP67 IP66, IP67
Ambient temperature, operation –40 °C... +60 °C –40 °C... +60 °C –40 °C ... +60 °C
OPERATING INSTRUCTIONS
46
O P E R A T I N G I N S T R U C T I O N S | WTB4S 8028211/2023/10/20 | SICK
Subject to change without notice
en

Table of Contents

Related product manuals