ARTDriveG Instruction manual Chapter 5 - Wiring Procedure • 55
Table 5.8.1.1: Braking Thresholds for Different Mains
Mains voltage Braking threshold
V
BR
[V]
220 Vac 390 Vdc
380 Vac 760 Vdc
460 Vac 760 Vdc
575 Vac 965 Vdc
agy0705
Table 5.8.1.2: Technical Data of the Internal Braking Units
Inverter Minimum
type I
RMS
I
PK
TR
BR
[A] [A] [s] [ohm]
1007 … 2040 4.1 7.8 19 100
2055 … 2075 6.6 12 16 67
3110 12 22 17 36
3150 17 31 16 26
4220 18 52 42 15
4300 37 23
4370 29 37
5450 … 5550 50 104 22 7.5
6750 … 71320
2002
2003
2005
3007
3010
3015 5.8 13 17 74
3020 10.3 23 16 42
4025 19 42 42 23
4030 19 42 23 23
4040 24 54 37 18
5050 24 54 37 18
5060 37 84 22 11,6
5075 37 84 22 11,6
7100 … 8200
agy0706
AGy…-4 (230V…480V)
External braking unit (optional)
78 10
External braking unit (optional)
AGy…-5 (575V)
4.4 9.7 16 100
3.1 6.9 19 140
I
RMS
: Nominal current of the braking unit
I
PK
: Peak current deliverable for 60 seconds max.
T : Minimum cycle time for a working at I
PK
for 10 seconds