92 • Chapter 7 - Parameters Description ARTDriveG Instruction manual
7.2 Menu d - DISPLAY
Basic
d.000 Output frequency
Drive output frequency [Hz].
d.001 Frequency ref (Frequency reference)
Drive frequency reference [Hz] .
d.002 Output current
Drive output current (rms) [A].
d.003 Output voltage
Drive output voltage (rms) [V].
d.004 DC link voltage
Drive DC Bus voltage (DC) [V].
d.005 Power factor
Drive output power factor.
d.006 Power [kW]
Drive output active power
d.007 Output speed
Calculated speed (d.000 * P.600).
d.008 Speed ref (Speed reference)
Calculated speed reference (d.001 * P.600).
Code LCD display [Code] & LCD select. Default MIN MAX Unit Variation IPA
d.000 Output frequency Hz 0.01 001
d.001 Frequency ref Hz 0.01 002
d.002 Output current A 0,1 003
d.003 Output voltage V 1 004
d.004 DC link voltage V 1 005
d.005 Power factor 0.01 006
d.006 Power [kW] kW 0.1 007
d.007 Output speed 0.01 / 1 008
d.008 Speed ref 0.01 / 1 009
Overload
d.050 Heatsink temp (Heatsink temperature)
Drive heatsink temperature [°C].
d.051 Drive OL (Drive overload)
Drive overload level (100% = alarm threshold).