Alphabetical Reference Description of functions
78
SNMP Server Address
•If an Æ SNMP server exists in the network, enter the Æ IP address of
this server here.
Standard address Æ page 96.
Æ page 53
SNMP Trap Port
Define the Æ Port here through which the Æ SNMP error messages
should be transmitted.
Æ page 53
SRSR Automatic Switch Back
Activate this checkbox for executing automatical change between
standby mode (emergency mode) and home mode (standard mode) of
the communication plattform.
Æ page 57
SRSR Enabled
Activate this checkbox if two communication plattforms are used
(Main-PBX und Standby-PBX).
Æ Gateway Address and Æ Subscriber Number of the Standby Æ PBX
must be entered Æ page 55.
Æ page 57
SRSR Switch To Home Expiry Timeout
Required waiting time for change from standby mode (emergency
mode) to home mode (standard mode). During this time a switch over
is not possible.
Valid values: 1 ... 255.
•Standard valueÆ page 96.
Æ page 57
SRSR Switch To Home Retry Count
Maximum number of negative attempts for switching over from home
mode (standard mode) to standby mode (emergency mode).
Valid values: 1 ... 255.
•Standard valueÆ page 96.
Æ page 57
SRSR Switch To Standby Expiry Timeout
Required waiting time for change from home mode (standard mode) to
standby mode (emergency mode). During this time a switch over is not
possible.
Valid values: 1 ... 255.
•Standard valueÆ page 96.
Æ page 57