PROFIBUS DP communication module
9.12 Data sets (BS)
3RW44 soft starters
Manual, 03/2017, NEB535219502000/RS-AB/008
189
Data set 72 - Logbook - Reading device errors
Table 9- 18 Data set 72 - Logbook - Reading device errors
0 - 3 Operating hours -
1 … 2
32
s 1 second Oldest entry
4 - 5 ID number of the device
error
0 … ±32767 s 1
6 - 9 Operating hours -
1 … 2
32
s 1 second Second oldest
entry
10 - 11 ID number of the device
0 … ±32767 s 1
120 - 123 Operating hours -
1 … 2
32
s 1 second Last, newest entry
124 - 125 ID number of tripping
0 … ±32767 s 1
This data set can accommodate 21 entries. When all locations have been written, the first
entry is overwritten again.
Note
The newest entry is entered at the end of the data set. The remaining entries are moved up
one entry.
The following messages can be entered:
452 Heatsink - thermistor defective
1467 Contact 2 failed