APPENDIX 1 PARAMETER LIST
Equipment type Editable item Parameter description
System Text System name
Station
- FC1820
- FC1840
- FC186X
Text Controller name
Login time Under 2nd/3rd level, if there is no operation in preset login time, controller
will automatically log out to 1
st
level. Effective value: 1-60 minutes.
Walk-test time When controller is being tested, it will automatically resume to normal status
after preset walk-test time, without the need of manual operation. Effective
value: 1-60 minutes.
Sound level Setup sound volume of beeper, with effective value of 0-7.When the value is
0, it is silence mode.
LCD closing time If there is no operation of controller in preset LCD off time, LCD will shut off
back light. Effective value: 1-60 minutes.
Main board input/output Text Main board input/output (default)
P2 line Text P 2 line#
Topology type Option 1: Stub
Option 2: Loop (default)
Power supply Text Power supply (default)
Interlocking panel Text Interlocking panel (default)
FDO181 smoke detector Text Device location description
Sensitivity Option 1: Standard (default)
Option 2: Sensitive
FDO181 heat detector Text Device location description
Detection mode Option 1: A2S (default)
Option 2: A2R
FDM181 manual call point Text Device location description
FDCI181 input module Text Device location/function description
FDCIO181 input/output
module
Text Device location/function description
Supervision input
(FDCI181&FDCIO181)
Text Device location/function description
Inversion Option 1: Normal (Active When NO is closed) (default)
Option 2: Inverting (Active when NC is open)
Supervision input
(interlocking panel and main
board input)
Text Device location/function description
Status input
(FDCI181&FDCIO181)
Text Device location/function description
Status input
(interlocking panel and main
board input)
Text Device location/function description
Alarm input
(FDCI181&FDCIO181)
Text Device location/function description

Table of Contents