107
LOGO! manual
EWA 4NEB 712 6006-02
Clock buffering at 40 _C Typically 8 h
Accuracy of the real-time clock
(LOGO! 230RC only)
Typically 5 s/day
Power loss of LOGO! 230R/RC
At 115/120 V AC
At 230/240 V AC
Typically 2.5 W
Typically 3 W
Digital inputs
Electrical isolation No
Input voltage L1
At signal 0
At signal 1
0V to 40V AC
79V to 265V AC
Input current
At signal 1
Typically 0.24 mA
At 230 V AC
Delay time
At 0 after 1
At 1 after 0
Typically 50 ms
Typically 50 ms
Line length
(unshielded)
100 m
Digital outputs
Output type Relay outputs
Electrical isolation Yes
In groups of 1
Continuous current I
th
Maximum 8 A
Relay type V23961-A1007-A302 (Siemens)
Incandescent lamp load
(25,000 switching cycles)
1000W (at 230/240 V AC)
500W (at 115/120 V AC)
Fluorescent tubes with electr. control gear
(25,000 switching cycles)
10 × 58W (at 230/240 V AC)
Fluorescent tubes, conventionally compensated
(25,000 switching cycles)
1 × 58W (at 230/240 V AC)
Fluorescent tubes, uncompensated
(25,000 switching cycles)
10 × 58W (at 230/240 V AC)
Short circuit-proof cos 1 Power protection B16
600A
Technical data