Chapter 7
Examples
RUGGEDCOM NETCONF
Reference Guide
114 Enabling an Ethernet Port
</eth>
</interface>
</config>
</edit-config>
</rpc>]]>]]>
5. Commit the changes:
<rpc message-id="234" xmlns="urn:ietf:params:xml:ns:netconf:base:1.0">
<commit/>
</rpc>]]>]]>
6. Unlock the candidate configuration:
<rpc xmlns="urn:ietf:params:xml:ns:netconf:base:1.0" message-id="235">
<unlock>
<target>
<candidate/>
</target>
</unlock>
</rpc>]]>]]>
7. Unlock the running configuration:
<rpc xmlns="urn:ietf:params:xml:ns:netconf:base:1.0" message-id="236">
<unlock>
<target>
<running/>
</target>
</unlock>
</rpc>]]>]]>
Section7.37
Enabling an Ethernet Port
In this example, multiple <rpc> requests enable an Ethernet port in the candidate configuration and then commit
the changes.
The following is the recommended procedure for making configuration changes on a device.
1. Lock the running configuration:
<rpc xmlns="urn:ietf:params:xml:ns:netconf:base:1.0" message-id="230">
<lock>
<target>
<running/>
</target>
</lock>
</rpc>]]>]]>
2. Lock the candidate configuration:
<rpc xmlns="urn:ietf:params:xml:ns:netconf:base:1.0" message-id="231">
<lock>
<target>
<candidate/>
</target>
</lock>
</rpc>]]>]]>
3. Discard uncommitted changes: