EasyManua.ls Logo

Siemens RX1400 - Committing Changes

Siemens RX1400
148 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RUGGEDCOM NETCONF
Reference Guide
Chapter 5
Changing Configuration Data
Committing Changes 51
The <error-path> element indicates where in the configuration the syntax error is found.
The <error-message> element provides a message, when one is available, describing the error.
The <bad-element> element indicates the element related to the error.
For more information on NETCONF errors, see Internet Engineering Task Force RFC 6241 Appendix A. NETCONF
Error List [http://tools.ietf.org/html/rfc6241#appendix-A].
Section5.2.6
Committing Changes
After making changes to the candidate configuration, you can commit the changes to make the changes active
in the running configuration. It is recommended that you first validate the candidate configuration before issuing
the commit command. For instructions on how to validate a configuration, refer to Section5.2.5, “Validating
Changes”.
To commit changes made to the candidate configuration, issue this command:
<rpc message-id="234" xmlns="urn:ietf:params:xml:ns:netconf:base:1.0">
<commit/>
</rpc>]]>]]>