RUGGEDCOM NETCONF
Reference Guide
Chapter 7
Examples
Checking an IP Address on a Specific Port using the
Interfaces Namespace 115
<rpc xmlns="urn:ietf:params:xml:ns:netconf:base:1.0" message-id="232">
<discard-changes/>
</rpc>]]>]]>
4. Enable the Ethernet port:
<rpc message-id="233" xmlns="urn:ietf:params:xml:ns:netconf:base:1.0">
<edit-config>
<target>
<candidate/>
</target>
<config>
<interface xmlns="http://ruggedcom.com/ns/rmf_if">
<eth>
<slot>lm4</slot>
<port>1</port>
<enabled/>
</eth>
</interface>
</config>
</edit-config>
</rpc>]]>]]>
5. Commit the changes:
<rpc message-id="234" xmlns="urn:ietf:params:xml:ns:netconf:base:1.0">
<commit/>
</rpc>]]>]]>
6. Unlock the candidate configuration:
<rpc xmlns="urn:ietf:params:xml:ns:netconf:base:1.0" message-id="235">
<unlock>
<target>
<candidate/>
</target>
</unlock>
</rpc>]]>]]>
7. Unlock the running configuration:
<rpc xmlns="urn:ietf:params:xml:ns:netconf:base:1.0" message-id="236">
<unlock>
<target>
<running/>
</target>
</unlock>
</rpc>]]>]]>
Section7.38
Checking an IP Address on a Specific Port using the
Interfaces Namespace
In this example, a single <rpc> request retrieves the IP address from a specified port.
The following is the typical procedure for querying data from the running configuration.
Request the data from the running configuration: