EasyManua.ls Logo

Siemens SCALANCE W786-1 RJ-45 - Page 144

Siemens SCALANCE W786-1 RJ-45
456 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuring with Web Based Management
6.4 "Information" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
144 Configuration Manual, 08/2018, C79000-G8976-C267-13
Description
Services
The "Services" list shows the security settings.
SSH Server
You configure the setting in "System > Configuration".
Enabled: Encrypted access to the CLI.
Disabled: No encrypted access to the CLI.
Web Server
You configure the setting in "System > Configuration".
HTTP/HTTPS: Access to the WBM is possible with HTTP and HTTPS.
HTTPS: Access to the WBM is now only possible with HTTPS.
SNMP
You can configure setting in "System > SNMP > General".
"-" (SNMP disabled)
Access to device parameters via SNMP is not possible.
SNMPv1/v2c/v3
Access to device parameters is possible with SNMP versions 1, 2c or 3.
SNMPv3
Access to device parameters is possible only with SNMP version 3.
Management ACL
You configure the setting in "Security > Management ACL".
Enabled: Restricted access only: Access is restricted using an Access Control List
(ACL).
Disabled: No access restriction: Management ACL is not enabled.
Enabled: No access restriction: Management ACL is enabled, but access is not
restricted using an Access Control List (ACL).

Table of Contents

Other manuals for Siemens SCALANCE W786-1 RJ-45

Related product manuals