EasyManuals Logo

Siemens SCALANCE W786-1 RJ-45 User Manual

Siemens SCALANCE W786-1 RJ-45
456 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #47 background imageLoading...
Page #47 background image
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
Configuration Manual, 08/2018, C79000-G8976-C267-13
47
Technical basics
4
4.1
Configuration limits for WBM and CLI
Configuration limits of the device
The following table lists the configuration limits for Web Based Management and the
Command Line Interface of the device.
Depending on your device, some functions are not available.
Configurable function
Maximum number
System
Syslog server 3
DNS server
manual (IPv4/IPv6)
3
learned (IPv4/IPv6)
2
in total
7
SMTP server
2
SNMPv1 trap recipient
10
SNTP server
2
NTP server
1
DHCP pools
1
IPv4 addresses managed by the DHCP server (dy-
namic + static)
100
DHCP static assignments per DHCP pool
20
DHCP options
20
Interfaces
Force destination addresses for roaming
10
Connected clients per VAP
126
Layer 2
Virtual LANs (port-based; including VLAN 1)
24
Multiple Spanning Tree instances
16

Table of Contents

Other manuals for Siemens SCALANCE W786-1 RJ-45

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W786-1 RJ-45 and is the answer not in the manual?

Siemens SCALANCE W786-1 RJ-45 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W786-1 RJ-45
CategoryWireless Access Point
LanguageEnglish

Related product manuals