Configuring with Web Based Management
6.5 "System" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
Configuration Manual, 08/2018, C79000-G8976-C267-13
253
Procedure
1. Click the check box in front of the line name you want to monitor to enable or disable the
monitoring function.
2. From the "PROFINET Redundancy" drop-down list, select the desired entry for redundant
power supply to be monitored by PROFINET.
3. Click the "Set Values" button.
6.5.16.2
Link Change
Configuration of fault monitoring of status changes on connections
On this page, you configure whether or not an error message is triggered if there is a status
change on a network connection.
If connection monitoring is enabled, an error is signaled
when there should be a link on a port and this is missing.
or when there should not be a link on a port and a link is detected.
If a fault occurs, the error LED lights up on the device. The currently pending error is
displayed under "Information > Errors".
In addition, the corresponding error message is entered in the result log table. The content of
the event log table is displayed in "Information > Log Tables > Event Log".

Table of Contents

Other manuals for Siemens SCALANCE W786-1 RJ-45

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W786-1 RJ-45 and is the answer not in the manual?

Siemens SCALANCE W786-1 RJ-45 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W786-1 RJ-45
CategoryWireless Access Point
LanguageEnglish

Related product manuals