Troubleshooting/FAQ
8.6 WLAN client Trigger handover via SNMP
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
Configuration Manual, 08/2018, C79000-G8976-C267-13
439
8.6
WLAN client Trigger handover via SNMP
If the other handover mechanisms such as Roaming threshold value, Background Scan
threshold value are inadequate, a specific handover can be triggered by setting the MIB
variable snMspsWlanForceHandover.
A WLAN client drives, for example along a stretch where there are several access points.
When the WLAN client passes a certain point, the value of the MIB variable is changed from
0 to 1. The WLAN client logs off from the connected access point and searches for
reachable access points. It logs on to the best reachable access point. The value of the MIB
variable is reset to 0.
Trigger handover
Using the private MIB variable snMspsWlanForceHandover, you can force a handover.
Note
With Web Based Management (WBM) or using the Command Line Interface (CLI) you
cannot configure this function.
OID of the private MIB variable snMspsWlanForceHandover:
iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).siemens(4329).industrialCo
mProducts(20).iComPlatforms(1).simaticNet(1).snMsps(1).snMspsCommon(1).snMspsWlan(27)
.snMspsWlanObjects(1). snMspsWlanSmt(1). snMspsWlanRoamingConfigTable(4). snMspsWlanR
oamingConfigEntry(1). snMspsWlanForceHandover(14)
values of the MIB variable
0: Function is disabled.
1: Triggers handover.
MIB file
The MIB variable snMspsWlanForceHandover can be found in the private MIB file
"Scalance_w_msps.mib".

Table of Contents

Other manuals for Siemens SCALANCE W786-1 RJ-45

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W786-1 RJ-45 and is the answer not in the manual?

Siemens SCALANCE W786-1 RJ-45 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W786-1 RJ-45
CategoryWireless Access Point
LanguageEnglish

Related product manuals