Configuring with Web Based Management
6.4 "Information" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
160 Configuration Manual, 08/2018, C79000-G8976-C267-13
Description
Radio
Shows the available WLAN interfaces.
WLAN Mode
Shows the transmission standard.
MAC Mode
Shows how the MAC address is assigned to the interface.
Automatic
The client automatically adopts the source MAC address of the first frame that it
receives over the Ethernet interface.
Manual
The address was entered manually.
Own
The client uses the MAC address of the Ethernet interface for the WLAN interface.
Layer 2 Tunnel
The client uses the MAC address of the Ethernet interface for the WLAN interface.
The network is also informed of the MAC addresses connected to the Ethernet
interface of the client. Up to eight MAC addresses can be used.