Configuring with Web Based Management
6.4 "Information" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
Configuration Manual, 08/2018, C79000-G8976-C267-13
179
Frames Deleted
Shows the number of frames not yet sent that were deleted from the queue due to the
iPRP delete frame.
Scanning Sync State
(in client mode only)
So that both clients do not search for an access point and change to the scan mode at he
same time they synchronize with each other.
Synchronization can have the following statuses:
idle: Idling No scanning
requested: Query to the partner client whether scanning is possible.
pending: Scanning is possible. Waits for the start of scanning and then changes to the
status "foreground" or "background".
background: Background scan is performed.
foreground: The client has, for example, just started up and is running a foreground
scan.