Configuring with Web Based Management
6.7 "Layer 2" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
Configuration Manual, 08/2018, C79000-G8976-C267-13
335
Description
The page contains the following boxes:
Spanning Tree
Enable or disable MSTP.
Protocol Compatibility
Select the compatibility mode of MSTP. For example if you select RSTP, MSTP behaves
like RSTP.
The following settings are available:
STP
RSTP
MSTP
Note
If iPCF mode is enabled, only the compatibility modes STP and RSTP are supported.
Procedure
1. Select the "MSTP" check box.
2. Select the compatibility mode from the "Protocol Compatibility" drop-down list.
3. Click the "Set Values" button.