Configuring with Web Based Management
6.7 "Layer 2" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
Configuration Manual, 08/2018, C79000-G8976-C267-13
343
Bridge Priority
Enter the bridge priority in this box. The value for the bridge priority is a whole multiple of
4096 with a range of values from 0 to 61440.
VLAN ID
Enter the VLAN ID. Here, you can also specify ranges with Start ID, "-", End ID. Several
ranges or IDs are separated by ",".
Permitted values: 1- 4094
Procedure
Creating a new entry
1. Enter the number of the MSTP instance in the "MSTP Instance ID" box.
2. Click the "Create" button.
3. Enter the identifier of the virtual LAN in the "VLAN ID" input box.
4. Enter the priority of the bridge in the "Bridge Priority" box.
5. Click the "Set Values" button.
Deleting entries
1. Use the check box at the beginning of the relevant row to select the entries to be deleted.
2. Click the "Delete" button to delete the selected entries from memory. The entries are
deleted from the memory of the device and the display on this page is updated.

Table of Contents

Other manuals for Siemens SCALANCE W786-1 RJ-45

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W786-1 RJ-45 and is the answer not in the manual?

Siemens SCALANCE W786-1 RJ-45 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W786-1 RJ-45
CategoryWireless Access Point
LanguageEnglish

Related product manuals