Upkeep and maintenance
7.3 Embedding firmware in ConfigPack.
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
Configuration Manual, 08/2018, C79000-G8976-C267-13
427
Procedure in the WBM
1. Connect to the WBM of the device on which you want to install the ConfigPack as
administrator.
2. Go to the menu "System > Load&Save".
3. In the row "ConfigPack", click the "Load" button
4. Select the ConfigPack you want to install.
5. Restart the device with "System > Restart".
If there is a different firmware version on the device to be installed compared with that in
the ConfigPack, an upgrade/downgrade of the firmware is performed. You can recognize
this by the red F-LED flashing (flashing interval; 2 sec on/0.2 sec off). Afterwards the
device is restarted and the device configuration incl. users and certificates stored in the
ConfigPack is transferred to the device.
6. Wait until the device has fully started up.
(the red F-LED is off)
7. You can log on the device again or exit the WBM.

Table of Contents

Other manuals for Siemens SCALANCE W786-1 RJ-45

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W786-1 RJ-45 and is the answer not in the manual?

Siemens SCALANCE W786-1 RJ-45 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W786-1 RJ-45
CategoryWireless Access Point
LanguageEnglish

Related product manuals