Technical specifications
7.7 SCALANCE X124
SCALANCE X-100
Operating Instructions, 12/2016, A2B00060666-08
57
Technical specifications
0 to 100 m
Max. 100 m IE FC TP Standard Cable with IE FC RJ45 Plug 180
Max. 90 m IE FC TP Standard Cable + 10 m TP Cord via IE FC RJ45 Outlet
Electrical data
Power supply Voltage range 18 to 32 VDC Safe Extra Low Voltage
(SELV)
Rated voltage
24 VDC
Design
4-terminal plug-in block
Signaling contact
Current
max. 100 mA
Rated voltage
24 VDC
Design
2-pin plug-in terminal block
Current consumption
Typical
200 mA
Power loss at 24 VDC
Typical
4.80 W
Permitted ambient conditions
Ambient temperature
During operation
-20 to +70
During storage
-40 to +80
During transportation
-40 to +80
Relative humidity
During operation
95 % no condensation
Operating altitude During operation 2,000 m above sea level at max. 56
ambient temperature
3,000 m above sea level at max. 50
ambient temperature
Design, dimensions and weight
Immunity to interference
EN 61000-6-2
Emission
EN 61000-6-3
Degree of protection
IP 30
MTBF (EN/IEC 61709, 40 °C)
49.3 years
Housing material Basic housing Die cast aluminum, powder coated
Front cover Polyphenylene ether + polystyrene
(PPE+PS plastic)
Weight
1500 g
Dimensions (W x H x D)
180 x 125 x 124 mm
Installation options
Installation on a DIN rail
Installation on an S7-300 standard rail
Wall mounting
Switching properties
Aging time
30 seconds
Max. number of learnable MAC ad-
dresses
2048
Response to LLDP frames
Blocking
Response to spanning tree BPDU
frames
Forwarding

Other manuals for Siemens SCALANCE X-100