EasyManua.ls Logo

Siemens SENTRON PAC3120 - Acquisition of Power Demand; Energy Counters

Siemens SENTRON PAC3120
160 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Description
2.3 Average values and counters
22
PAC3120 and PAC3220
Equipment Manual, 10/2019, L1V30425208F-01
2.3.2 Acquisition of power demand
Values that can be read out
The power monitoring devices supply the power demand of the last completed demand
period:
Average values for active power and reactive power, separated in each case for import
and export
Minimum and maximum within the period
Length of the demand period in seconds. The period may be shorter due to external
synchronization.
Time in seconds since the last synchronization or since completion of the last period
Note
The power demand can only be read out via the interface (it is not shown on the display).
The average values of the last demand period can only be retrieve
d during the active
demand period.
Example: Period length and length of the demand period
Period length: 15 min; time of day: 13:03; time in seconds: 180 s.
The following can be calculated from this: The last demand period ended at 13:00. The
active demand period will end at 13:15 or in 12 min.
Adjustable parameters
Time interval in minutes: 1 to 60 min adjustable, default 15 min
Synchronization via bus or digital input
2.3.3 Energy counters
Energy counters
The power monitoring devices have energy counters for recording
Active energy import
Active energy export
Reactive energy import
Reactive energy export
Apparent energy

Table of Contents

Related product manuals