Fault Finding
Sicore II Installation and Commissioning Guide
667/HB/52600/000 Issue 2 Unrestricted
80
Fault Item to check / possible fault
Low recognition rate Check camera frame rate (as observed on ANPR Live View page),
expected to be around 25 frames per second. Low frame rate could
be caused by poor retro-reflection (see above).
Try adjusting the camera field of view to optimise road coverage
(see section 7.6)
Verify that the ANPR country configuration (ref section 7.7) is set
correctly for the nationality of the plates being observed.
Table 17 – Fault Finding