Commissioning
Sicore II Installation and Commissioning Guide
667/HB/52600/000 Issue 2 Unrestricted
69
7.7. ANPR Engine
The ANPR engine needs to be pre-configured with the expected nationalities of the plates it is
to capture. As default the camera is configured for GB plates with a generic (X_EU)
configuration to cover European countries.
Select the ANPR Engine – Country Modules menu by navigating to :
Status and Configuration / ANPR / ANPR Engine / Country Modules
The following default menu will be displayed:
Figure 37 – ANPR Engine Country Modules
Change ID1 to the primary country in which the camera is to be used with the ID2 being left
(for Europe) as X_EU. Multiple nationalities (or multiple plate formats within a single
country) can be configured by using the Add Row and defining each country in turn.